IT floor
Two rows of racks facing the outer aisles. The contained rear aisle between them carries only power and water, so the floor stays clear for people and hardware.
Whitespace, power, cooling and connectivity from one ecosystem: modular datacenter infrastructure engineered together, so what lands on site is a working system rather than a construction project.
WhitespaceData Room2 level whitespace moduleWhitespace for the densest AI hardware, fully wired, piped and FAT-tested. Built for up to +300 kW per rack.
WhitespaceUtility BridgePower, cooling and cabling overheadUtilities on an open frame above the racks, so the floor stays clear and the layout follows the hardware.
PowerE-HousePower distributionPower distribution in a factory-built module, delivered tested and ready to connect.
CoolingCoolingMechanical yard: pumps, dry coolers, chillersHeat rejection chosen per site and climate: dry coolers, chillers, cooling towers or heat recovery.
SupportStorage/OfficeSupport spacesOffice, storage, meet-me-room and vestibule modules, built with the same factory process.Every product connects to the next.See how they come together in the six solutions 2 level whitespace module
The data hall of an AI and HPC data center, factory-built for the densest hardware. IT on the ground floor, power and piping on the level above, delivered wired, piped and FAT-tested, ready to connect.

Pick a part of the hall to see what it does and where it sits.
Two rows of racks face the outer aisles; the contained rear aisle carries only power and water.
Grating walkways above the racks. Power and cooling are serviced here, away from the IT.
A busway per row with plug-in tap-offs at every rack position, added or moved without a shutdown.
A stainless steel loop to every rack: about 85% of the heat leaves through direct liquid cooling, ready for up to +300 kW per rack.
Fibre and copper trays run on the utility level, straight above the rack rows.
Power, water and fibre enter through feed-through plates and flanges on the end wall, ready to connect to the data center network infrastructure on site.


IT work and maintenance on power and cooling never get in each other's way.
Two rows of racks facing the outer aisles. The contained rear aisle between them carries only power and water, so the floor stays clear for people and hardware.
Grating walkways with busways, tap-off boxes, fibre trays and the headers of the liquid loop, the chilled water and the facility water. Power and cooling are serviced up here, above the IT and out of the way of the people working on it.


Busways from four sources, two at every rack position, with plug-in tap-offs and branch metering. Tap-offs are added or moved without a shutdown. UPS and switchgear sit in the E-Houses next door.
Liquid first: around 85% of the heat leaves through direct liquid cooling at the chip, via in-row CDUs at the row ends and a stainless steel loop to every rack. Rear door heat exchangers on a separate loop take the rest. Built for future density, up to +300 kW per rack.
Aspirating smoke detection and inert gas suppression in every hall, inside a fire-rated steel envelope. No water near the hardware.
Secured entrance doors, access control, CCTV and intrusion detection, linked to the security zones of the site.
BMS and power monitoring pre-wired in the factory, with leak detection and drip trays under the piping. Ready to connect to your DCIM.
Insulated steel modules with ESD flooring, engineered for seismic loads and for transport by road, built to European structural standards.
Typical values for one data hall. Exact figures depend on the project.
Every Kontena data center is built from the same hall. Add halls, and they become a power block; repeat the block, and it becomes a campus.
A complete data room: racks, busways, piping and safety systems in one factory-built hall.
Edge single clusterTwo halls with five E-Houses and their own mechanical yard, linked by a corridor spine.
Repeatable MDC blockPower blocks repeat side by side, built in parallel and brought live phase by phase.
Full scale facilityYes. A compact module of 9.0 x 3.0 x 4.0 m holds 8 rack positions at about 100 kW each, 150 kW and above where needed. It travels by road without escort and has corner castings for sea freight.
Any. We are vendor-independent: you choose the racks, CDUs and rear doors, or we supply and integrate them in the factory.
Yes. The same halls are placed inside existing buildings as sealed, insulated rooms. See Indoor retrofit.
Yes. For lower densities the hall is fitted for air cooling only; the structure and the factory process stay the same.
Well-defined projects can have the first modules ready five to six months after engineering starts. Exact timing depends on the project.
Yes. New halls connect to the corridor spine beside the running ones, without interrupting operation.
We come back with a first configuration and a schedule.