Data center solutions: six ways to build
Modular data center solutions from a single cluster to a large campus, outdoors or inside an existing building. Every solution uses the same factory-built, FAT-tested blocks; what changes is the scale and the setting.
On your own plot.
Complete data centers on your own plot. Four ways, from a single cluster to a full campus.
Inside a building.
The same engineering inside a building. Only the envelope is different.
Modular stick built
Plant outside, compute inside. A weather-tight hall around the compute; Kontena makes the data center in and around it.
Indoor


- 2 sidesE-Houses on one, mechanical yard on the other
- Overheadpower, cooling and cabling on the Utility Bridge
- 0plant inside the white space
- 100%factory-built and FAT-tested
Plant outside, compute inside.
The building stays a building. The engineering is identical to any other Kontena build; only the envelope is different.
A new hall around the compute: weather-tight, snow-rated, dust-free and thermally stable, with the planning and insurance profile of a normal industrial hall.
Inside, the Utility Bridge carries power, cooling and cabling on an open frame above the racks, so the floor stays clear.
E-Houses line up along one wall, outside the hall, stacked on two levels.
The mechanical yard runs along the other wall. Noise, heat, vibration and maintenance traffic stay out of the white space.
A building around the compute.
Some clients build a hall anyway. These are the reasons we hear.
- PlanningA hall fits the local rules where open-air plant does not.
- InsuranceThe risk profile of a normal industrial hall.
- Harsh climateSnow, wind, dust or salt stay outside.
- A tight envelopeWeather-tight, thermally neutral and dust-free around the compute.
- Reconfigurable floorUtilities overhead, so the layout follows the hardware.
- Plant outsideServicing, swapping or expanding without entering the data hall.
The Utility Bridge.
Power, cooling and cabling on an open steel frame above the racks: factory-built, FAT-tested, and extended row by row as demand grows.

The building and the data center, in parallel.
The hall goes up on site while the data center is built in our halls.
- 01Hall and layout
Hall, rows and plant positions fixed early.
- 02Built in our halls
Utility Bridge, E-Houses and cooling built in parallel.
- 03FAT-tested
Every assembly tested before it ships.
- 04Hall closed
The envelope goes up while the parts are in production.
- 05Set and connected
Bridge bolted together, racks placed, plant connected outside.
- 06Live
Commissioned and handed over.
Exact timing depends on the project.
Questions about modular stick built
Who builds the hall?
We deliver the data center in and around it, and can include the hall in the same contract, or work with your builder.
Can we use a hall we already have?
Only if it is clean, closed, dust-free and keeps a steady temperature, like a new hall. Older buildings get sealed data rooms instead: see Indoor retrofit.
Can the rack layout change later?
Yes. The utilities run overhead on the Utility Bridge, so racks can move and rows can be added without touching the floor.
How is the plant serviced?
From outside the hall: E-Houses on one side, the mechanical yard on the other. Nobody needs to enter the data hall.
Tell us your load, your site and your timeline.
We come back with a first configuration and a schedule.