Data center solutions: six ways to build

Modular data center solutions from a single cluster to a large campus, outdoors or inside an existing building. Every solution uses the same factory-built, FAT-tested blocks; what changes is the scale and the setting.

Open a solution to see everything about it.
06 · Indoor deployment

Modular stick built

Plant outside, compute inside. A weather-tight hall around the compute; Kontena makes the data center in and around it.

Indoor
Render of Utility Bridges in a hall, running above rows of black racksRender of the Utility Bridge with the Kontena logo, above two rows of racks in an empty hallIsometric render of a modular stick built data center: rows of racks in a new hall, E-Houses along one wall, cooling units outside
Example: Utility Bridges above rows of racks, between the columns of a hallExample: one Utility Bridge above two rows of racksExample: E-Houses on one side of the hall, the mechanical yard on the other
  • 2 sidesE-Houses on one, mechanical yard on the other
  • Overheadpower, cooling and cabling on the Utility Bridge
  • 0plant inside the white space
  • 100%factory-built and FAT-tested
How it is built

Plant outside, compute inside.

The building stays a building. The engineering is identical to any other Kontena build; only the envelope is different.

  1. A new hall around the compute: weather-tight, snow-rated, dust-free and thermally stable, with the planning and insurance profile of a normal industrial hall.

  2. Inside, the Utility Bridge carries power, cooling and cabling on an open frame above the racks, so the floor stays clear.

  3. E-Houses line up along one wall, outside the hall, stacked on two levels.

  4. The mechanical yard runs along the other wall. Noise, heat, vibration and maintenance traffic stay out of the white space.

01020304
Example layout: two rack rows under each Utility Bridge, E-Houses and mechanical yard outside.
Why a hall

A building around the compute.

Some clients build a hall anyway. These are the reasons we hear.

  • PlanningA hall fits the local rules where open-air plant does not.
  • InsuranceThe risk profile of a normal industrial hall.
  • Harsh climateSnow, wind, dust or salt stay outside.
  • A tight envelopeWeather-tight, thermally neutral and dust-free around the compute.
  • Reconfigurable floorUtilities overhead, so the layout follows the hardware.
  • Plant outsideServicing, swapping or expanding without entering the data hall.
Inside the hall

The Utility Bridge.

Power, cooling and cabling on an open steel frame above the racks: factory-built, FAT-tested, and extended row by row as demand grows.

Render of the Utility Bridge above two rows of racks in an empty hall
From plan to live

The building and the data center, in parallel.

The hall goes up on site while the data center is built in our halls.

  1. 01Hall and layout

    Hall, rows and plant positions fixed early.

  2. 02Built in our halls

    Utility Bridge, E-Houses and cooling built in parallel.

  3. 03FAT-tested

    Every assembly tested before it ships.

  4. 04Hall closed

    The envelope goes up while the parts are in production.

  5. 05Set and connected

    Bridge bolted together, racks placed, plant connected outside.

  6. 06Live

    Commissioned and handed over.

Exact timing depends on the project.

FAQ

Questions about modular stick built

Who builds the hall?

We deliver the data center in and around it, and can include the hall in the same contract, or work with your builder.

Can we use a hall we already have?

Only if it is clean, closed, dust-free and keeps a steady temperature, like a new hall. Older buildings get sealed data rooms instead: see Indoor retrofit.

Can the rack layout change later?

Yes. The utilities run overhead on the Utility Bridge, so racks can move and rows can be added without touching the floor.

How is the plant serviced?

From outside the hall: E-Houses on one side, the mechanical yard on the other. Nobody needs to enter the data hall.