Vendor-independent by design
We're the architect and integrator, not a component manufacturer, so hardware-agnostic isn't a claim, it's how we're built. Your racks, your suppliers, your choice, today and tomorrow.




Turn-key data center infrastructure, prefabricated and ready for the densest AI and high performance computing (HPC) hardware, from a single data room to a full campus.
AI capacity is now limited less by chips than by the buildings that house them.
Power connections and conventional construction take two years or more. Racks keep getting denser while the walls go up, and operators have to commit to a design long before they know which hardware will go into it.
Kontena takes time out of that equation. Modules are built in the factory while the site is prepared, and every design leaves room for the next generation of hardware.
Start small and add scale incrementally. Capacity increases with demand, so there is no overinvestment up front and no capacity sitting idle waiting for a load that has not arrived yet.
High performance computing solutions engineered from the ground up for density, performance and efficiency: liquid-first cooling and high-density power distribution, built for GPU clusters rather than adapted to them.
Prefabricated modules mean rapid, predictable deployment with far less on-site complexity. What lands on site is a tested system, not a construction project.
Modular data center solutions from a single cluster to a large campus, outdoors or inside an existing building. Every solution uses the same factory-built, FAT-tested blocks; what changes is the scale and the setting.
Outdoor · 01 to 04Indoor · 05 and 06
View all solutions side by side

Campus scale. Built in repeatable blocks.
At 20 MW and beyond, schedule and coordination decide whether a project succeeds. Kontena delivers large AI and HPC data centers turn-key, built from the same proven blocks we use for a single deployment. The blocks are produced in parallel and delivered in phases, so capacity comes online while the rest is still in production.
Example: 75 MW full scale data center design
01 / 06


One complete data center. Factory-built, ready to run.
Start operating your live modular data center and grow on the same site, one block at a time. Every block is the same proven design: data rooms, power, cooling and connectivity, engineered together and delivered fully wired, piped and FAT-tested. Each new block goes in beside the last, while the first keeps running.
Example: 5 MW data center deployment
02 / 06

Compute where you need it. Live in months, not years.
Some compute belongs next to the data it processes: for latency, for sovereignty, or because moving it costs more than housing it. Edge is a micro data center that brings ~1 MW of AI capacity to a factory floor, a campus or a remote site, fully wired, piped and factory-acceptance-tested, ready to connect and run.
Example: 1 MW edge data center design
03 / 06

Any size, any shape. Designed around your project.
No two sites are the same, so no two designs are either. We start from what your project brings: available power, plot size and shape, climate, height limits, noise and permit rules, IT load, rack density, redundancy and timeline. From there we combine our building blocks, resize them, stack them or spread them out, and engineer custom parts where needed.
Example: 2.5 MW data center deployment
04 / 06
Your building becomes the data center.
An existing hall rarely offers what a data center needs: the envelope leaks, there is no temperature control, and dust and damp move freely. That does not rule the building out, only its use as the shell. So we place sealed, insulated, temperature-controlled data rooms inside it.
Example: 20 MW data center deployment inside an existing building
05 / 06

Plant outside, compute inside.
Not everyone wants their infrastructure standing in the open. Some are building a hall anyway, for planning reasons, for insurance, for a harsh climate, or because they want a weather-tight, thermally neutral, dust-free envelope around their compute. Others already have one.
A campus scale Kontena data center: every part factory-built, FAT-tested and delivered ready to connect.
Hover or tap a number to see what each block does.
What separates Kontena from a component vendor, a general contractor, and anyone selling a catalog module.
We're the architect and integrator, not a component manufacturer, so hardware-agnostic isn't a claim, it's how we're built. Your racks, your suppliers, your choice, today and tomorrow.
Integrated design, MEP specialists worldwide and German steel production at industrial scale. One contract, one accountable team, no hand-offs.
Standard blocks configured to your site, and fully custom building blocks where the site, the regulations or the load demand it. The fit is custom; the lead time isn't.
Up to +300 kW per rack, with a dual-loop system that removes almost all heat at the chip. Heat rejection is chosen per site and climate: dry coolers, chillers, cooling towers or heat recovery.
Everyone promises speed; almost no one guarantees it. Factory-built and factory-tested modules let us commit to a price and a date before we start, and hold them.
Site brokerage, feasibility, engineering, build, MEP and operations under one roof. If you don't have a site yet, we can find one, and then build on it.
Traditional builds run one discipline after another; we run them in parallel. Long-lead equipment is released at contract award, and the moment the permit lands, fabrication design is done and site works begin. Modules arrive FAT-tested and are connected as they land, leaving only setting, hook-up and commissioning on site.
From permit to live capacity, against a well-run traditional build.
Earning capacity before a traditional build goes live.
Indicative schedule from our reference example. First modules can be ready in as little as five to six months after engineering start. Exact timing depends on the project.
A 40 MW campus built in 10 MW phases. Designed once, then fabrication, deployment and commissioning overlap across phases: the first 10 MW goes live 7 months after the permit, with a new phase every 6 weeks. A traditional build delivers all 40 MW at once, in about 22 months.
First 10 MW live, the full 40 MW by month 11.5.
Of full site revenue before the traditional site opens.
40 MW in four phases of 10 MW
A new 10 MW phase goes live every 6 weeks. A traditional build delivers all 40 MW at once.
Indicative schedule for a 40 MW reference campus. Exact timing depends on the project.
A data center built in a factory from purpose-engineered steel modules. Whitespace, power, cooling and utility infrastructure are fully wired, piped and tested before leaving the works, then assembled on site. Most of the build happens off-site under controlled factory conditions.
Kontena cuts what traditionally takes three to five years down to ten to fourteen months from engineering start to first modules operational, with the rest of the site still in production while early modules already run.
No. A container data center starts from a shipping container; a Kontena modular data center does not. We build all our steel modules from the ground up, which makes every kind of modularity possible: local space restrictions, the amount and type of hardware inside the modules, your own requirements and more.
Two coordinated loops work together. The DLC loop captures over 90% of heat directly at the chip and runs deliberately warm, cutting pumping energy and enabling free cooling for most of the year. A second loop with Rear Door Heat Exchangers keeps the whitespace stable and condensation-free, all year round.
We support virtually any rack density, from tens to hundreds of kilowatts per rack. Because the cooling is liquid-first by design, the platform scales with each new GPU generation rather than being locked to today's hardware.
As low as 1.06, thanks to the liquid-first cooling design.
Yes. Because the DLC loop deliberately runs warm, the captured heat can feed district heating, natural heat sinks or combined strategies, rather than being rejected as waste.
Yes. Every module (whitespace, E-House, cooling, power) is a standardized building block, so adding capacity means repeating what already works, without redesign or downtime. Performance and efficiency stay constant from a single unit to a full campus.
Yes. Kontena is fully vendor-independent: any brand of busbar, CDU or cooling plant can be integrated, and the platform adapts to your stack where needed. Alternatively, we can propose our preferred brands and products, always in consultation with you.
In many cases, yes. Kontena modules can be sited outdoors on a prepared slab or fitted within a suitable existing building shell, depending on the space, structural and access constraints of the site. For indoor installations, the Utility Bridge is designed to route power, cooling, cabling and fire protection overhead within the existing structure.
We come back with a first configuration and a schedule.