Solutions overview

Data center solutions: six ways to build

Modular data center solutions from a single cluster to a large campus, outdoors or inside an existing building. Every solution uses the same factory-built, FAT-tested blocks; what changes is the scale and the setting.

Open a solution to see everything about it.
04 · Outdoor deployment

Custom data center design

Any size, any shape. Designed around your project. No two sites are the same, so no two designs are either.

Outdoor
Render of a custom Kontena data center design on a hillside: green clad stacked modules and a raised cooling deckRender of a 2.5 MW Kontena system: two data rooms beside an elevated deck with dry coolersRender of a 5 MW Kontena modular data center block at sunset on an industrial site: two data room levels beside the raised cooling platform
Example: 2.5 MW data center deploymentExample: 2.5 MW system, two data rooms beside a raised cooling deck, with E-House on topExample: 5 MW block with stacked plant on an industrial site
  • Any sizefrom one cluster to a campus
  • 9parameters that shape the design
  • 1factory process, standard or custom
  • 100%factory-built and FAT-tested
Every parameter counts

We start from your project.

Everything your site and your load bring goes into the design, before a single module is drawn.

  • Available powerWhat the grid gives today, and when it grows
  • Plot size and shapeLong, narrow, sloping or split
  • ClimateHeat, cold, snow, dust or salt in the air
  • Height limitsWhat the permit allows above ground
  • Noise and permit rulesDistance to neighbours, acoustic limits
  • IT loadFrom a few MW to a full campus
  • Rack densityAir-cooled racks to direct liquid cooling
  • RedundancyThe availability your customers expect
  • Budget and timelineWhen the first capacity must earn
Standard blocks

Combined to fit.

We combine our building blocks, resize them, stack them or spread them out, and engineer custom parts where needed.

  1. Data hall, E-Houses and the cooling yard side by side at ground level, using the full plot. Easy access, simple maintenance, room to grow.

  2. Two data room levels stacked on top of each other, with the cooling plant on a raised steel deck above the power. More capacity on every square meter.

  3. Halls, rows and module lengths sized to the plot shape, the height limit or the IT load.

  4. Bespoke parts only where they are needed: an enclosed link to an existing building, a pipe bridge that brings the heat to it, a special enclosure or an acoustic screen.

  5. The same data room can wear a different skin: large panels, timber slats or brick. Cladding makes the site look like a real building, in your own colors, with your logo or text on the walls.

The same blocks, combined in different ways. Highlighted: what changes.
Standard where possible, custom where needed

Proven blocks, bespoke parts.

Standard blocks

  • Data rooms and data halls
  • E-Houses and transformers
  • Mechanical yard: pumps, dry coolers, chillers
  • Meet-me-room, storage, office
  • Controls, monitoring and safety systems
  • The same tests and the same suppliers

Custom where needed

  • Module sizes and hall lengths
  • Stacked plant on a small plot
  • Acoustic screens and special enclosures
  • Heat recovery to a network or a process
  • Cladding and branding
  • Interfaces with an existing site
  • UL and NFPA versions for North America, 60 Hz
From brief to live

Designed around your project.

The design follows your site; the build follows our factory process.

  1. 01Your site and load

    Power, plot, climate, permits, IT load, density and timeline.

  2. 02Concept and layout

    Our blocks combined, resized, stacked or spread out on your plot.

  3. 03Custom parts engineered

    Bespoke parts only where the project needs them.

  4. 04Built in our halls

    The same factory process as every Kontena data center.

  5. 05FAT-tested

    Every module tested before it ships.

  6. 06Assembled on site

    Set, connected and commissioned.

Exact timing depends on the project.

FAQ

Questions about custom designs

How custom can it get?

As custom as your site needs. We start from proven blocks and change only what the project asks for, so the lead time stays short.

Is a custom design slower?

Only in the design phase. Engineering the custom parts of the site and the modules takes extra time; everything built to our standard specifications stays as it is. Once production starts, the timing is the same as for a standard build.

Can you work with our architect or engineer?

Yes. We work with your design team, or take the full design on ourselves.

Do you build for North America?

Yes. Next to IEC and EN, we build to UL and NFPA, for 60 Hz grids and the building codes of the site, with the switchboards and UPS listed for the US market.

What do you need from us to start?

Your load, your plot and your timeline. With the grid connection and the permit situation we can make a first configuration.

Get in touch

Tell us your load, your site and your timeline.

We come back with a first configuration and a schedule.

sales@kontena.beKontena BV, Nieuwe Westweg 10, 2040 Lillo, Belgium