Data center solutions: six ways to build

Modular data center solutions from a single cluster to a large campus, outdoors or inside an existing building. Every solution uses the same factory-built, FAT-tested blocks; what changes is the scale and the setting.

Open a solution to see everything about it.
01 · Outdoor deployment

Full scale facility

Campus scale. Built in repeatable blocks. At 20 MW and beyond, schedule and coordination decide whether a project succeeds. We deliver large AI and HPC data centers turn-key, built from the same proven blocks we use for a single deployment, produced in parallel and delivered in phases.

Outdoor
Aerial render of a full scale Kontena data center campus with data halls, cooling yards, offices and parkingRender of a Kontena campus in green hills: a black data hall building with dry coolers on the roof, white buffer tanks and an access roadAerial render of a Kontena data center campus at sunset, with a lake and green landscape around it
Example: 75 MW full scale data center designExample: data halls with their cooling yard and buffer tanks, in a valleyExample: the complete scope of a campus, from substation to gatehouse
  • One contractfrom groundworks to handover
  • Phase by phasecapacity live while the rest is still in production
  • 100%of the blocks factory-built and FAT-tested
  • 20 MW+typical campus scale, indicative
How it is built

Built up layer by layer.

Every campus is built up from the same layers. Each layer is a set of factory-built blocks that connect to the one below.

  1. Groundworks, foundations, cable and pipe routes, roads and fencing for the whole plot. Done once, at the start, while the blocks are in production.

  2. Grid connection and substation, transformers, stacked E-Houses with switchgear, UPS and distribution, and gensets for backup power.

  3. Two level data halls for high-density AI and HPC racks: IT on the ground floor, power and piping on the level above. A corridor spine links the halls to the E-Houses.

  4. A platform against the data halls with dry coolers and chillers on top and pump skids below, chosen per site and climate and piped in the factory.

  5. Meet-me-room, offices, storage and logistics, gatehouse, entrance security and parking.

0102030405
Example layout: a 38 MW campus in four power blocks of 9.6 MW, each with two data halls, five E-Houses and its own mechanical yard.
Benefits

Why work with Kontena.

Earning while you build

The first power block runs while the next ones are still in production, so the campus earns from month seven instead of at the end.

One party for the whole plot

Groundworks to handover, data halls to gatehouse: one contract and one team that answers for all of it.

Every block a copy

Each power block repeats the last: the same design, the same suppliers, the same tests. The tenth block is as predictable as the first.

Vendor-independent

Your racks, your switchgear and UPS brands. A supplier who cannot hold a date is routed around, not waited on.

Ready for the next GPU generation

Liquid first, with rack positions provisioned for 300 kW, so the campus follows the hardware instead of limiting it.

Heat as a resource

The warm liquid loop is ready for district heating or industry next door, at a scale where the heat really counts.

One contract

One contract, the whole plot.

We deliver turn-key, from groundworks and foundations through to commissioning and handover. The scope covers everything on the site: data halls, power and cooling, but also offices and storage buildings, roads, fencing, entrance security and parking.

  • Groundworks and foundations
  • Grid connection
  • Data halls
  • Power and backup power
  • Cooling and heat rejection
  • Meet-me-room
  • Offices, storage and logistics
  • Roads, fencing and entrance security
  • Parking
  • Commissioning and handover
Aerial render of a Kontena data center campus under construction: data halls, a large cooling yard and two tower cranesAerial render of a full scale data center campus with data halls, plant yards, office building, gatehouse and parking
Example: a campus under construction, data halls and cooling yard going up togetherOne contract covers everything on the plot, from substation to gatehouse
Delivered part by part

Your campus, phase by phase.

The site is prepared once. Then the campus fills up one phase at a time: while one phase goes live, the next is being set beside it and the one after is in production in our halls.

Phase 1 live. The first phase is commissioned and live. Phase 2 is being set beside it, phases 3 and 4 are in production.

  • Live
  • Being set and commissioned
  • In production in our halls
  • Planned
GatehouseParkingOffices · storageMMRGrid connectionPhase 1Phase 2Phase 3Phase 4

Example of a campus in four phases. Exact phasing and timing depend on the project.

FAQ

Questions about the full scale facility

How big can the data center become?

There is no fixed limit. One hall is about 4.8 MW IT. Two halls with their own mechanical yard make a power block of 9.6 MW IT, and power blocks repeat side by side. Campuses of 40 MW and beyond are built this way.

Can the data center get cladding, colors or logos?

Yes. The outside is a finish, not a constraint. Cladding, colors and logos can follow your brand or the planning requirements of the site, for example timber cladding. Tell us early so it goes into the design.

Can we build it in phases?

Yes. Blocks are delivered and brought live one after the other, while the earlier blocks keep running. You grow at the pace of your demand.

How fast can we go live?

Well-defined projects reach the factory acceptance test around five months after the design is frozen, and go live a few weeks after delivery. On a campus the blocks are built in parallel. Exact timing depends on the project.

Does it need a building?

No. The blocks stand outdoors on prepared foundations. If you want to place a data center inside a building, see Indoor retrofit and Modular stick built.

Which hardware and cooling does it support?

Any rack hardware. We are vendor-independent, and the blocks are designed for high density with direct liquid cooling or rear doors, as your racks need.

What do you take care of?

We support you from early concept and site design through assembly to turn-key operations. What Kontena takes on in your project is agreed in one contract.

What do you need from us to start?

Your load in MW, your site (or the search for one) and a target date. We come back with a first configuration and a schedule.

Get in touch

Tell us your load, your site and your timeline.

We come back with a first configuration and a schedule.

sales@kontena.beKontena BV, Nieuwe Westweg 10, 2040 Lillo, Belgium